Quoting a Fine-Bubble Aeration Package? Send These 7 Numbers First

A fine-bubble aeration package is one of the easiest wastewater purchases to get wrong on paper. Two suppliers quote the same tank, and the prices come back far apart — one with disc diffusers, one with tube diffusers, one including the air headers and drop legs, the other pricing diffusers only. Neither quotation is necessarily wrong. They are simply answering different questions, because the enquiry never gave them the same numbers to work from.

The pattern is familiar to anyone who has bought MBBR media or a screw press: the supplier who has to guess will guess in their own favour. Aeration makes it worse, because the package has more parts than it appears to — diffusers, membranes, holders, headers, drop legs, gaskets, fixings, sometimes a blower — and each can be left out without the headline price changing shape.

This article lists the seven numbers to send before you ask for a price, explains what each one decides, and shows how to compare the quotations that come back.

What an Aeration Quotation Should Cover

Before judging a price, check what it contains. A complete fine-bubble aeration quotation states, in writing:

  • The diffusers — type (disc or tube), quantity, diameter or length, and membrane material.
  • The air distribution — headers, drop legs, supports and fixings, and whether the pipework is included or supplied by others.
  • The blower, if included — many diffuser quotations exclude the blower entirely, so confirm whether one is in the price.
  • Spares and tools — membranes, gaskets and any special tools for replacement, priced as a first-year set or listed separately.
  • Documentation — a layout drawing of the diffuser grid in your tank, an installation guide, and the membrane material certificate.

If the blower is excluded, the quotation should say so in one line. The most expensive surprise in aeration buying is not the diffuser price. It is discovering that the air supply, the pipework, or the spares were never in the scope.

The 7 Numbers to Send

1. Tank dimensions and water depth

Send the internal length, width and water depth of each tank, plus a drawing or sketch if one exists. Water depth decides the diffuser layout more than any other single figure: it sets how the grid is arranged, how many diffusers fit, and what the air pressure at the diffuser must overcome. A quotation written for a 4-metre tank will not work in a 6-metre tank, and a supplier who is never told the depth will quote a standard grid and leave the correction for later.

If the tank is an existing one being retrofitted, include photographs of the floor, the existing pipework entries, and any obstructions such as mixers, walkways or retention screens. Retrofits are where the missing-data problem is worst, because the supplier cannot see what is already in the tank.

2. Design airflow — or the blower you already have

State the design airflow in cubic metres per hour, or the normal and maximum airflow your process design calls for. If you do not have a design airflow figure, state the blower you already own — make, model, rated flow and pressure — and let the supplier work from that. What matters is that the supplier is working from your air supply, not from a catalogue assumption.

Do not ask the supplier to invent the airflow for you. The airflow a tank needs is set by your process design, and HNS supplies equipment packages, not whole-plant process design. Your engineer sets the demand; the supplier’s job is to deliver it evenly through the diffuser grid and to state, in writing, the airflow per diffuser their quotation is based on.

3. Oxygen demand and dissolved-oxygen target

Send the dissolved-oxygen target your process is designed to hold, and the load the aeration system must serve, as set by your process design — for example, the design BOD load for the tank. The supplier does not need to redo your process calculations, and a buyer-side article is not the place for sizing formulas. But the supplier does need to know the target, because a grid designed for a low oxygen target and a grid designed for a high one are different grids.

4. Disc or tube — state your preference, or ask for both

Disc diffusers and tube diffusers suit different tanks and different maintenance routines, and the choice changes the price, the layout and the spares list. If your specification already calls for one type, state it. If it does not, ask the supplier to quote both and to state the reasons for their recommendation — tank shape, access for maintenance, air distribution, and membrane replacement routine are the factors that usually decide it.

Our technical site compares the two types from the selection side, and it is the right place to read before you decide. What matters for the quotation is that the two suppliers you compare are pricing the same type, or that you know exactly why they are not.

5. Membrane material — EPDM or silicone

State the membrane material you want, or ask the supplier to state what they are offering and why. EPDM and silicone differ in temperature tolerance, chemical resistance and cost, and the wrong choice in oily, hot or aggressive wastewater will show up as cracked or hardened membranes long before the diffuser itself fails.

Ask the supplier to state the membrane material, thickness and expected service notes in writing. Our 2026 guide on replacing diffuser membranes covers what to confirm before ordering a membrane alone; a full aeration package quotation should answer the same questions for the whole grid, not just for the spare part.

6. Layout constraints — fixed grid or retrievable system

Say how the diffusers will be installed and maintained: a fixed grid on the tank floor, or a retrievable and liftable system that can be pulled out without draining the tank. This one choice changes the hardware, the installation cost and the downtime of every future membrane change. A buyer with no drainage window needs a retrievable system; a buyer with a tank that is drained annually may not.

Also state anything unusual about access: a covered tank, a tank with limited crane access, or a tank that cannot be taken out of service. The supplier who knows the constraints will design around them; the supplier who does not will quote the standard grid and charge for the change later.

7. Spares and first-year wear parts

Ask for a priced spares list with the quotation: spare membranes, gaskets, holders and any special tools. Membranes are wear parts, and the first membrane change arrives sooner than most buyers expect. A quotation that includes a first-year spares set is more expensive on paper and cheaper in practice than one that leaves you ordering single membranes at emergency freight rates.

How to Compare Two Aeration Quotations

Once you have two complete quotations, compare them on the same lines:

CheckWhat to look for
Diffuser type and quantitySame type, quantity stated, grid layout drawing included
Airflow per diffuserStated in writing, matched to your design airflow
Membrane materialEPDM or silicone stated, matched to your water
Headers, drop legs, fixingsIncluded, or priced separately and clearly
BlowerIncluded or explicitly excluded
SparesFirst-year set priced, not left as an afterthought
DocumentationLayout drawing, installation guide, material certificate

If one quotation is much cheaper, the difference is almost always in one of those rows — fewer diffusers, no pipework, no blower, or no spares. Find the row before you sign.

What to Send HNS for a Quotation

Send us the seven items above: tank dimensions and water depth, design airflow or your existing blower data, dissolved-oxygen target and design load as set by your process design, your preference for disc or tube diffusers (or ask us to quote both), membrane material preference, installation and access constraints, and the spares scope you want priced.

Aeration equipment is manufactured at HNS’s own factory in Yixing, alongside our MBBR media, sponge media and clarifier equipment, so the quotation you receive states the diffuser type, membrane material and grid layout as manufactured — not as a trader’s catalogue line. We supply media and equipment packages; whole-plant process design, civil works, commissioning and operation remain outside our scope, and your process engineer stays in charge of those decisions.

If the aeration package is part of a larger upgrade — most often an MBBR system or a new aeration system for an existing basin — tell us about the whole project in the enquiry, so the diffuser grid, the media volume and the blower are quoted against the same tank data instead of three different assumptions.

The Short Version

A comparable aeration quotation needs seven things from you: tank dimensions and depth, airflow, oxygen target, diffuser type, membrane material, installation constraints, and spares. Send those seven, require the supplier to answer in writing on the same seven, and the cheapest quote will usually stop looking cheap — because it was never the same scope. Send the seven to HNS and we will quote on exactly that basis.

Contact HNS for a fine-bubble aeration quotation — include the seven numbers above and we will reply with a written quotation you can compare line by line.