A first media order is a fresh start: empty tank, chosen carrier, known quantity. A top-up is none of those things. The tank already holds media with a history — model, size, density, fill level, years of wear — and the new media has to live alongside it, move with it, and be held back by the same screens. Order media that does not match and the result is not just a disappointing top-up: mixed carriers that separate in the tank, screens that hold one size and pass another, new media ending up where the old never went.
The buying question is therefore different from a first order: not “which carrier is best?” but “which carrier matches what I already have — and if it does not match, what changes with it?” This guide answers that question before you pay, so the top-up adds capacity instead of problems. The technical side of adding capacity to an existing MBBR is on our technical site, in the retrofit data guide; this article stays on the procurement decisions.
First, identify exactly what is in the tank
A top-up cannot be specified from memory. Before you ask any supplier for a price, establish four facts about the media already installed. If you cannot establish one, say so — a supplier who knows what is unknown can help you find out, usually from a sample; one who is not told will guess.
The model and size. The carrier’s model name matters less than its dimensions, because the screen aperture, the behaviour in the water, and the surface area all follow from size and shape. Our range covers eight models, and the differences are not cosmetic:
| Carrier model | Size (mm) | Catalogue surface area |
|---|---|---|
| MBBR19 | φ25 × 12 | >650 m²/m³ |
| MBBR37 | φ25 × 12 | >800 m²/m³ |
| MBBR64 | φ25 × 4 | >1,200 m²/m³ |
| MBBR76 | φ25 × 4 | >1,600 m²/m³ |
| MBBR40 | φ15 × 15 | >900 m²/m³ |
| MBBR04 | φ11 × 7 | >900 m²/m³ |
| MBBR05 | φ11 × 7 | >1,000 m²/m³ |
| MBBR06 | φ16 × 10 | >800 m²/m³ |
If your media came from another maker, send its dimensions or a sample piece — a handful of carriers photographed next to a ruler is enough to identify the size class. Do not rely on a trade name alone; the same name has been applied to different sizes by different makers, and a top-up ordered on a name is a gamble.
The material and density. Our carriers are 100% virgin HDPE with a density of 0.96–0.98. Density decides whether a carrier floats, sinks, or hangs in the water column — and two carriers of the same size but different density will not move together. If your existing media is a different material or a different density, say so; mixing densities is the fastest way to end up with one carrier crowded at the surface and the other sitting at the bottom.
How much is in there now. You do not need to calculate anything — you need the facts a supplier can work from: the tank’s working volume from your drawings, the fill level as it stands (how full the tank looks, or how many bags went in at the last fill, at 0.1 m³ per bag for our packing), and whether media has been lost over time. Media does get lost — through screens, overflows, and during cleaning — so tell the supplier what you can observe now, not what was on the original order.
The condition of the old media. Old carriers tell a story: intact or chipped at the edges, biofilm even or patchy, any softening or colour change. A top-up into a tank where old media is breaking up is a different purchase from one where it is sound — in the first case, part of your order replaces losses rather than adding capacity, and the supplier should know that before quoting. Photograph a handful of old carriers, wet and dry, and send the photos with your enquiry.
Match first, then decide whether to change
The simplest top-up is like-for-like: the same model, material, and density — and in most cases the right one. It mixes evenly, passes the same screens, and needs no change to aeration or retention. If your existing media is performing and the only problem is that there is not enough of it, do not let a top-up become an experiment. Order the match.
There are three situations where a change is worth considering — and each of them needs a conversation with the supplier, not a unilateral switch on the order form:
- The old model is no longer made, or no longer the best fit. Then the question is which current model is closest in size and density, and whether the screens still hold it. A finer carrier — MBBR64 or MBBR76 at φ25 × 4, for example — needs a finer screen than a chunkier one, and the screen change may cost more than the media saving.
- You are adding sponge media to a plastic-media tank, or the reverse. Our NovusPore sponge media — protected surface area above 5,000 m²/m³ by the BET method, porosity above 98% — compresses, holds water, and moves differently from rigid plastic carriers. Mixing sponge and plastic in one tank is a decision to discuss with the supplier first, not to discover after delivery. Our guide to testing a media sample is the right first step before any mixed fill.
- The old media is failing. If carriers are breaking up or wearing fast, matching them exactly reproduces the problem. But the fix may be a different material or a different duty, not a different model — and the supplier needs the failure story, with photos and timing, before recommending anything.
In all three cases, agree the change before the order, with the screen and aeration consequences stated — not discovered at the first fill.
How much to order — and what to send instead of a calculation
Buyers often ask for a formula for top-up volume. There is no safe one to print here: the answer depends on your tank, your existing fill, and what the top-up is meant to achieve, and a wrong figure stated confidently is worse than no figure at all. Send the supplier the data the quantity follows from, and let the quantity come back on the quotation, where it can be questioned:
- Tank working volume, from drawings or a measured level.
- Existing fill: model, approximate volume or bag count, and how full the tank looks now.
- What the top-up is for: replacing losses, raising the fill towards the top of the catalogue dosing range of 15–65% of tank volume, or adding a second stage.
- The screens: aperture, if known, and whether they will hold the new carrier.
- Delivery constraints: whether the media goes in during an outage, and whether the tank can be drained.
That list is also the test of a good quotation: it should state the model, the volume, the number of bags, and the basis, so you can check it against your own tank. A quotation stating only a volume, with no basis, should be sent back with questions.
Order a small margin, not a large one. Media keeps — our plastic carriers carry a catalogue service life above 15 years — but a large surplus of a model you may not reorder is dead stock, and a small shortfall can be covered by a follow-up bag order. Receiving is the same as for a first order; our delivery, receiving and first-fill checklist covers what to check when the bags arrive.
The checklist: before you send a top-up enquiry
| Item | Have you got it? |
|---|---|
| Existing carrier model and dimensions | Named, or a sample photographed with a ruler |
| Material and density | Stated, or the old media’s origin named |
| Existing fill | Tank volume, bag count or observed fill level |
| Condition of old media | Photos, wet and dry, with any breakage noted |
| Screen aperture | Known, or the screen described so the supplier can confirm it holds the new carrier |
| Purpose of the top-up | Replacing losses, raising fill, or adding a stage |
| Sample decision | Whether a sample of the new carrier is wanted first |
If more than two boxes are empty, the enquiry is not ready — the supplier’s first reply will be questions, not a price.
What to send HNS for a top-up quotation
Send us the carrier model and dimensions you run now, or a sample; the tank working volume and the fill as it stands; photos of the old media; and what the top-up is meant to do. If you are considering a change of model, or adding sponge media to a plastic tank, say so in the first message — we will confirm the match, the screens, and the consequences before quoting, and say plainly if like-for-like is the better answer.
We manufacture the MBBR carrier range and the NovusPore sponge media at our own factory in Yixing, and we supply media and equipment packages — not whole-plant process design, civil works, commissioning, or operation. Send the details through our contact page, and we will quote the top-up with the model, volume, and basis stated on the offer, so the new media lands in a tank it matches.