Most wastewater plants were built to remove three things: solids, organic matter, and nutrients. A fourth target is now arriving in European regulation — micropollutants: pharmaceutical residues, PFAS, and other trace substances that pass through conventional biological treatment largely untouched.
If you are planning a biofilm upgrade in the next two or three years, this matters to you even if your plant is not in Europe. European regulation is where discharge standards for micropollutants are being set first, and equipment and design practice follow the regulation. The question is not whether micropollutants will affect your plant. It is whether the upgrade you are about to buy will still be the right one when they do.
This article is a buyer’s guide to that question. It does not promise that any biofilm media removes micropollutants. It explains what the fourth treatment stage is, where biofilm fits in it — and where it does not — and what to check before you spend money on an upgrade that will have to live with the new rules.
The buying problem: an upgrade bought today, judged by tomorrow’s standard
A biofilm upgrade is a long-lived purchase. Media stays in a tank for years, screens and aeration grids longer. If the discharge standard changes halfway through that life, the plant faces a second upgrade — or a retrofit of a retrofit.
That is the risk the new European rules create. Under the recast Urban Wastewater Treatment Directive, large treatment plants will need a fourth treatment stage for micropollutants, and the cost is to be shared with the producers of the pharmaceuticals and cosmetics that put those substances into the water — the extended producer responsibility (EPR) provisions. The details are still contested: the pharmaceutical industry body EFPIA called for a pause on the EPR provisions on 12 October 2026, and the Court of Justice case C-193/25 is still in progress, with the Advocate General’s opinion issued on 3 September 2026. National laws transposing the directive are due by 31 July 2027.
Those dates matter because they define the uncertainty. The direction — a fourth stage for micropollutants — is set. The timetable, the exact list of substances, and who pays are not. Any supplier who tells you today that a specific media or process is “quaternary-treatment ready” is selling a certainty that does not yet exist. The right response is to buy an upgrade that stays useful whatever the final rules say.
What actually decides it: where biofilm fits, and where it does not
Quaternary treatment is not a bigger version of biological treatment. It is a different job, done by different processes — typically ozonation or activated carbon adsorption, placed after the biological stage. Micropollutants are present at trace concentrations, and removing them needs either chemical oxidation or adsorption, not more bacteria.
That distinction decides where biofilm fits:
Biofilm is the foundation, not the fourth stage. A stable biological stage is what makes a fourth stage affordable. Ozone and activated carbon both work better — and cost less to run — when the water arriving at them is already low in organic matter and solids. A biofilm upgrade that improves COD and ammonia removal therefore helps a future fourth stage, even though the biofilm itself is not doing the micropollutant removal. Think of it as preparing the ground: the better the biology, the smaller and cheaper the fourth stage can be.
Biofilm does not replace the fourth stage. No MBBR carrier or sponge media should be sold to you as a micropollutant solution. Biofilm can contribute to the breakdown of some biodegradable micropollutants, but that contribution is variable, substance-dependent, and not something any responsible supplier should put a removal percentage on. If a quotation promises micropollutant removal from a media change alone, treat that as a warning sign, not a selling point.
The upgrade decision changes in one practical way. When the fourth stage arrives, it will sit downstream of your biology and will need space, power, and a stable feed. An upgrade that consumes every square metre of available footprint, or that leaves no room for a downstream unit, can make the fourth stage much more expensive to add later. That is a real buying consideration today: leave space and hydraulic head for what comes next, even if you do not yet know exactly what it will be.
What to check before you specify media for an upgrade
Four checks, all of which you can do before any quotation is requested:
1. Is your discharge consent likely to gain a micropollutant limit, and when? If your plant discharges to a sensitive water body, serves a large population, or is in the EU, the answer is probably yes, and the date is probably within the life of the media you are about to buy. Ask your regulator or your design consultant directly. A plant with no such prospect can ignore this article; a plant with one cannot.
2. Does the upgrade improve the water that a future fourth stage would receive? Ask the supplier for the expected effluent quality after the upgrade — COD, suspended solids, ammonia — and compare it with what an ozone or carbon stage would need as its inlet. If the upgrade leaves the effluent rough, the fourth stage will be larger and more expensive. If it leaves it clean, the fourth stage gets cheaper.
3. Does the upgrade leave room — physically and hydraulically — for a downstream stage? Check the footprint around the biological tanks, the available hydraulic head, and the power supply. An upgrade that fills the last available space is a bet that no fourth stage will ever be required. That bet is getting harder to justify in Europe, and in any market that follows European standards.
4. Is the supplier honest about what biofilm cannot do? This is the simplest test of all. Ask directly: “Will this media remove micropollutants, and by how much?” A supplier who gives you a number is either guessing or selling. A supplier who says “no, that is a separate stage, and here is how our upgrade prepares for it” is the one to buy from.
What to send HNS for a quotation
If you are planning a biofilm upgrade and want it to be compatible with a future fourth stage, send the same data any good media quotation needs — plus two extra items:
- Current and target effluent quality — flow, COD, BOD, ammonia, total nitrogen and suspended solids, as measured and as required.
- Tank dimensions and free volume — including what is already in the tank.
- Existing media and screens — type, fill ratio, and whether they stay or are replaced.
- Influent character — including any industrial discharge and its variability.
- Shutdown window — how long the tank can be out of service.
- Whether a micropollutant limit is expected — and if so, which substances and what timetable your regulator has indicated.
- Space and head available downstream — footprint, hydraulic head and power available for a future additional stage.
Those last two items cost nothing to include, and they change the advice you get back. A supplier who knows a fourth stage is coming will recommend differently — not different media, but a different layout, a different effluent target, and a different conversation about what the upgrade is for.
The mistake to avoid
The expensive mistake here is not buying the wrong media. It is buying the right media for the wrong standard — an upgrade designed to meet today’s consent, installed in a plant that will be judged by tomorrow’s.
Biofilm media is a good investment in that future, but only if it is bought as preparation, not as a solution. The media that earns its keep is the media that leaves the water cleaner, the plant with room to grow, and the buyer with an honest statement of what it does and does not remove. Anything else is a quotation that will look cheap until the fourth stage arrives.
Next step: send HNS the seven items above through the contact page and ask for a biofilm upgrade quotation that states the expected effluent quality and the space and head left for a downstream stage. If a micropollutant limit is on your horizon, say so in the inquiry — it changes the recommendation, and it costs nothing to mention.
Related reading: our MBBR system and MBBR media pages carry the verified media figures behind this article, and NovusPore sponge media covers the high-surface-area option for volume-limited tanks. Policy dates in this article are stated as of November 2026; the EU timetable and substance list may change as the directive is transposed.