Clarifier Upgrades: Tube Settlers, Dosing and Flotation for Clarifiers That Can’t Keep Up
An overloaded clarifier does not automatically mean a new clarifier. Most settling stages fail for one of three reasons — not enough settling area, chemistry that never lets the solids form a settleable floc, or solids too light to settle at all — and each reason has a cheaper fix than concrete. This page walks through the three upgrade routes in the order we check them.
35 / 50 / 80 mm
tube diameters (HNS-TS range)
60°
tube inclination
109 m²/m³
specific surface area, TS35
Symptoms first
Symptoms first
Solids carrying over the weirs. A sludge blanket that keeps rising toward the surface. Clear water that turns cloudy at peak flow. These are the symptoms of a clarifier running beyond its design — and they are the first thing we ask about, because the symptom tells us which of the three routes is most likely to work.
Three routes
The three routes
| If the problem is… | The route | The product |
|---|---|---|
| Not enough settling area | Add tube settlers | Tube settler media |
| Poor floc formation | Fix the dosing first | Chemical dosing system |
| Light or oily solids | Switch to flotation | DAF system |
Send us your flow, effluent solids and tank dimensions — we tell you which route fits, including when the honest answer is a new tank.
The components
The components

DAF System
dissolved air flotation for light and oily solids, quoted per project against your water data.
Sizing in brief
Tube settlers — the sizing in brief
Tube size follows your solids: 35 mm gives the most area for well-pretreated water, 50 mm is the standard for secondary clarifiers, 80 mm passes heavy solids more freely. Modules are welded to your clarifier’s dimensions and sit on a support frame at 60°. Send the clarifier size and flow and we calculate the settler area — the full parameter table is on the product page.
How it works
How an upgrade assessment works with us
You send the brief: clarifier dimensions, design and peak flow, influent solids, and what you observe at the weirs. We come back with a route, a product list and a price — or a recommendation for a new tank if the numbers say the existing one cannot be saved.
Frequent questions
FAQ
It depends on your current surface loading and how far beyond it you are — anyone quoting a fixed percentage without your flow and tank size is guessing. Send the numbers and we calculate it.
Yes — modules are cut and framed to the tank geometry, circular included. Send the diameter and a photo of the existing internals.
If your floc is poor, yes — settlers multiply area, but they cannot settle solids that never formed a floc. We check the chemistry first when the water tells us to.
When the solids float rather than sink — oils, greases, light biological flocs, algae. DAF is quoted per project against tested water data, not from a catalogue table.