Clarifier Upgrades: Tube Settlers, Dosing and Flotation for Clarifiers That Can’t Keep Up

An overloaded clarifier does not automatically mean a new clarifier. Most settling stages fail for one of three reasons — not enough settling area, chemistry that never lets the solids form a settleable floc, or solids too light to settle at all — and each reason has a cheaper fix than concrete. This page walks through the three upgrade routes in the order we check them.

35 / 50 / 80 mm

60°

109 m²/m³

Symptoms first

Symptoms first

Solids carrying over the weirs. A sludge blanket that keeps rising toward the surface. Clear water that turns cloudy at peak flow. These are the symptoms of a clarifier running beyond its design — and they are the first thing we ask about, because the symptom tells us which of the three routes is most likely to work.

Three routes

The three routes

If the problem is…The routeThe product
Not enough settling areaAdd tube settlersTube settler media
Poor floc formationFix the dosing firstChemical dosing system
Light or oily solidsSwitch to flotationDAF system

The components

The components

Tube settler media

Tube Settler Media

PP/PVC inclined tubes, 35/50/80 mm, welded modules sized to your clarifier, frames on request.

Chemical dosing pump

Chemical Dosing System

automatic coagulant and polymer dosing sized to your flow, so the chemistry stops being guesswork.

Dissolved Air Flotation(DAF) System

DAF System

dissolved air flotation for light and oily solids, quoted per project against your water data.

Sizing in brief

Tube settlers — the sizing in brief

Tube size follows your solids: 35 mm gives the most area for well-pretreated water, 50 mm is the standard for secondary clarifiers, 80 mm passes heavy solids more freely. Modules are welded to your clarifier’s dimensions and sit on a support frame at 60°. Send the clarifier size and flow and we calculate the settler area — the full parameter table is on the product page.

How it works

How an upgrade assessment works with us

You send the brief: clarifier dimensions, design and peak flow, influent solids, and what you observe at the weirs. We come back with a route, a product list and a price — or a recommendation for a new tank if the numbers say the existing one cannot be saved.

Frequent questions

FAQ

It depends on your current surface loading and how far beyond it you are — anyone quoting a fixed percentage without your flow and tank size is guessing. Send the numbers and we calculate it.

Yes — modules are cut and framed to the tank geometry, circular included. Send the diameter and a photo of the existing internals.

If your floc is poor, yes — settlers multiply area, but they cannot settle solids that never formed a floc. We check the chemistry first when the water tells us to.

When the solids float rather than sink — oils, greases, light biological flocs, algae. DAF is quoted per project against tested water data, not from a catalogue table.

Send us this, get an assessment

  • Clarifier dimensions or diameter
  • Design & peak flow
  • Influent suspended solids
  • The problem you see (carryover / blanket / peak washout)
  • Chemicals you currently dose
  • Photos of the existing clarifier, if available